0 Cookie Img

DC-SE Series

DC-SE Series
DC-SE Series
Product Code : 516
Product Description

DC-SE Series
General Purpose LVDT


Description :

The DC-SE series has been designed to meet today's requirements for operation from a singleended power supply. The output is also singleended over the full range displacement of the LVDT making the unit compatible with unipolar inputs on analog-to-digital converters and programmable logic controllers, etc.

Parameter

DC-SE 100

DC-SE 250

DC-SE 500

DC-SE 1000

DC-SE 2000

DC-SE 4000

DC-SE 6000

Stroke range

0.10 [2.54]

0.25 [6.35]

0.50 [12.7]

1.0 [25.4]

2.0 [50.8]

4.0 [101.6]

5.0 [152.4]

Sensitivity, VDC/inch

50

20

10

5

2.5

1.25

0.833

Sensitivity, VDC/mm

1.97

0.787

0.394

0.197

0.098

0.0492

0.0328

Input voltage

+8.5 to +28VDC

Line regulation

1mV/VDC, maximum; 0.2mV/VDC, typical

Input current

10mA maximum; 6mA typical

Output voltage

0 to +5VDC (4 wire), +1 to +6VDC (3 wire) - Increases when the core is displaced towards the cable

Output current

5mA maximum

Non-linearity

±0.25% of FR, maximum

Output ripple & noise

10 mVRMS, maximum

Stability

0.125% of FSO

Temp. coefficient of sensitivity

0.028%/ºF [0.05%/C], maximum

Frequency response

200 Hertz @ -3dB

ENVIRONMENTAL SPECIFICATIONS & MATERIALS

Temperature range

-13°F to +185°F [-25°C to 85°C] Operating; -65°F to +257°F [-55°C to 125°C] Survival

Shock survival

250 g (11ms half-sine)

Vibration tolerance

10 g up to 2kHz

Housing material

AISI 400 Series stainless steel

Electrical connection

Cable with 4 conductor, 28AWG, stranded copper, braided shield and polyurethane jacket, 39 inches [1 meter] long


Contact Us

A-401, Kailash Industrial Complex, Behind Godrej Colony, Vikroli (W), Mumbai, Maharashtra, 400079, India